SAMPLING

Sampling System for Liquids

DIN-EN: DN 15 – 100 / PN 10 – 40
ASME: NPS ½“ – 4“ / class 150 – 300
PT range: -40 < T < 230°C, vacuum 10-8 mbar

Download
Design Features

Design Characteristics

  • closed system
  • cavity free
  • spilling eliminated and contamination free
  • specific defined representative sample quantity
  • pressure free sampling (positive overlap)
  • simple and fool safe operation
  • absolutely tight
  • utility model
  • fugitive emmission resp. clean air act certified (TA – Luft 2002 approval)
  • Directive 2014/68/EU
Ausfuehrungen-SAMPLING

Standard Design

Standard DesignTYPE ATYPE B
applicationfor high-toxic liquid mediafor less toxic resp. polluted media
bottle connectionneedle system and bottle protectionPTFE-adaptor
sample bottlesclear glass or SCHOTT-DURAN labaratory bottle with ISO-threadclear glass or SCHOTT-DURAN labaratory bottle with ISO-thread
bottle volume(VF)60, 100, 250, 500 ml
60, 100, 250, 500 ml
standard diaphragm
(Septum)
rubber/ PTFE
temperature (Tmax)230°C230°C
Needle diameter2, 4, 6 mm6, 8, 10, 15 mm

Bottle connection

  • PTFE-Adapter: for laboratory bottle with ISO-thread GL 32/45. Application: For less toxic resp. polluted media.
  • Clamping Retainer: For fast and easy exchange of laboratory bottle, even for heated version.
  • Needle system: closed needle system for laboratory bottle with septum (Butyl and PTFE). Needle System NH and NH-S with diverse internal diameter(2-6 mm). Application for high toxic resp. polluted media for spillnig eliminated an contamination free sampling.
Sampling-Flaschen-GB
PT-Diagram

Operating temperatures < -30°C and > 220 °C have to be checked and approved by AZ according to the operating conditions.

Besides the P/T value of the sleeve the limitations of the valve bodies also have to be considered. Please refer to the EN 12516-1 resp. ASME B16.34 in order to choose a proper pressure rating (PN/class). The shown values refer to austenitic stainless steel 1.4408 (A351 Gr. CF8M).

1) For operating temperatures below -10°C low temperature / austenitic steels are required.
2) Sleeve: There are different sleeve materials / compounds available.

Materials

Standard body materials

  • Carbon Steel 1.0619, ASTM A216 WCB
  • Stainless Steel 1.4408, ASTM A351 CF8M
  • Stainless Steel 1.4308, ASTM A351 CF8
  • Unalloyed stainless steel casting (low Temp.) 1.1138, LCC/LCB/A352

Standard plug materials
• Stainless Steel 1.4408, ASTM A351 CF8M
• Stainless Steel 1.4308, ASTM A351 CF8

Special materials
• Alloy
• Monel
• Nickel
• Zirconium
• Titan
• Tantal
• other materials on request

Lining materials(TRF + TRF-A)
• PFA, PFA-conductive, FEP

Sealing Systems

Type STD

Standard sealing for all major applications;
Tmax 230°C

Type FS

Firesafe sealing (API 607) with graphite packing for additional
stem sealing; Tmax 230°C

Type CA

Chemical sealing to prevent fugitive emission of aggressive and toxic media
with PTFE packing for additional stem sealing; Tmax 230°C

Type FSN

Firesafe safety sealing (API 607) for fluctuating temperatures
with 3x graphite packing (adjustable) for additional
stem sealing; Tmax 280°C

Type FSN-SL

Firesafe safety sealing (API 607) for fluctuating temperatures
with 3x graphite packing (live loaded disc springs) for additional
stem sealing; Tmax 280°C

Type CASN

Chemical safety sealing for fluctuating temperatures
with 3x PTFE packing (adjustment) for additional stem sealing;
Tmax 230°C

Type CASN-SL

Chemical safety sealing for fluctuation temperatures
with 3x PTFE packing (live loaded disc springs) for additional
stem sealing; Tmax 230°C

Port Forms
Dimensions
Actuation

1 Locking Devices
Pilot valve combinations, pad lock eyelets, linear key conception, indexing plunger arrestor.

2 Actuators
Actuators for mounting-flange acc. to DIN ISO 5211

3 Cover extension
Solid construction in stainless steel, Standard extension 100 mm or 150 mm high, non standard lengths are available on request . Hexagonal bolts on adjustment ring freely accessible. Note: Don’t use with sealing FSN/FSN-SL and CASN/CASN-SL