LG-SP Sampling Systems

Reliable Liquid Gas Sampling

Design Features

Design Characteristics

  • closed system
  • simple and safe operation
  • representative an contamination free sample
  • defined sampling quantity
  • integrated system purge
PT-Diagram

Operating temperatures < -30°C and > 220 °C have to be checked and approved by AZ according to the operating conditions.

Besides the P/T value of the sleeve the limitations of the valve bodies also have to be considered. Please refer to the EN 12516-1 resp. ASME B16.34 in order to choose a proper pressure rating (PN/class). The shown values refer to austenitic stainless steel 1.4408 (A351 Gr. CF8M).

1) For operating temperatures below -10°C low temperature / austenitic steels are required.
2) Sleeve: There are different sleeve materials / compounds available.

Materials

Standard body materials

  • Carbon Steel 1.0619, ASTM A216 WCB
  • Stainless Steel 1.4408, ASTM A351 CF8M
  • Stainless Steel 1.4308, ASTM A351 CF8
  • Unalloyed stainless steel casting (low Temp.) 1.1138, LCC/LCB/A352

Standard plug materials

  • Stainless Steel 1.4408, ASTM A351 CF8M
  • Stainless Steel 1.4308, ASTM A351 CF8

Special materials

  • Alloy
  • Monel
  • Nickel
  • Zirconium
  • Titan
  • Tantal
  • other materials on request
Sealing Systems

Type STD

Standard sealing for all major applications;
Tmax 230°C

Type FS

Firesafe sealing (API 607) with graphite packing for additional
stem sealing; Tmax 230°C

Type CA

Chemical sealing to prevent fugitive emission of aggressive and toxic media
with PTFE packing for additional stem sealing; Tmax 230°C

Type FSN

Firesafe safety sealing (API 607) for fluctuating temperatures
with 3x graphite packing (adjustable) for additional
stem sealing; Tmax 280°C

Type FSN-SL

Firesafe safety sealing (API 607) for fluctuating temperatures
with 3x graphite packing (live loaded disc springs) for additional
stem sealing; Tmax 280°C

Type CASN

Chemical safety sealing for fluctuating temperatures
with 3x PTFE packing (adjustment) for additional stem sealing;
Tmax 230°C

Type CASN-SL

Chemical safety sealing for fluctuation temperatures
with 3x PTFE packing (live loaded disc springs) for additional
stem sealing; Tmax 230°C